Technical specifications and design profile details
Vacuum Dryer is designed keeping in view, the sensitive indirect heat required for carrying out the drying process cycle.
- MATERIAL OF FABRICATION: AISI 304
- DRYER CHARGE CAPACITY: 2 KGS
- MAXIMUM OPERATING TEMPERATURE: 100 0C
- NO. OF CHARGE LOADING TRAYS: 04 NOS.
- Cubical in geometrical shape and double walled for hot water
- Convenient front loading feature
- Front closing door provided with food grade sealing gasket
- Manual air admittance wall provided
- Pressure control valve provided for preset low and high pressure control
- Convenient material loading food grade (Four) Trays are provided
- Easy quick release KF standard flange fittings and, for pump isolation manually operated ball valve is provided
- Designed for wide working pressure(vacuum) range,15mm to 760mm hg
- Adequate ceramic felt external insulation to keep the body (skin) temperature to normal above ambient levels
- Sensitive working operating temperature range with close controlling accuracy + /- 0.5 0c.
- System operating panel with temperature display and pressure (vacuum)
- Water ring vacuum pump for clean and oil free process chamber environment
- Water heating system provided with adequate water storage tank and low-level water preventive device.
- Fore line cold trap unit for condensing the generated water vapor during process cycle.
- Chiller unit provided for circulating the chilled water through fore line trap (condenser)
WATER CHILLER UNIT CAPACITY : 2TR
TEMPERATURE MAINTAINED : 15 0C
COMPRESSOR MAKE : EMERSON/DANFOSS
REFRIGERENT USED : 407 C
POWER : 3 PH+N(380-415-50 HZ)
- For process parameters monitoring and control HMI and temperature indicator provided.
Salient Safety Features
ALL NECESSARY INTERLOCKINGS PROVIDED
- Hot water storage tank provided with low water level sensing device which prevents the system from running with insufficient water
- Interlocking provided between hot water circulation pump and double walled process chamber water circulation outlet pressure sensing switch
- Heating system is safeguarded with temperature controller which controls the set temperature within the required range
- HMI controller provided to monitor and control all the process parameters